title: "Update 2025-09-26"
author: "Rodrigo Arias Mallo"
date: 2025-09-26
---
This is a summary of notable changes introduced in the last two years. We
continue to maintain all machines updated to the last NixOS release (currently
NixOS 25.05).
### New compute node: fox
We have a new [fox machine](/fox), with two AMD Genoa 9684X CPUs and two NVIDIA
RTX4000 GPUs. During the last months we have been doing some tests and it seems
that most of the components work well. We have configured CUDA to use the NVIDIA
GPUs, as well as AMD uProf to trace performance and energy counters from the
CPUs.
### Upgraded login node: apex
We have upgraded the operating system on the login node to NixOS, which now runs
Linux 6.15.6. During the upgrade, we have detected a problem with the storage
disks. The `/` and `/home` partitions sit on a
[RAID 5](https://en.wikipedia.org/wiki/Standard_RAID_levels#RAID_5),
transparently handled by a RAID hardware controller which starts its own
firmware before passing the control to the BIOS to continue the boot sequence. A
problem during the startup of the firmware prevented the node to even reach the
BIOS screen.
After a long debugging session, we detected that the flash memory that stores
the firmware of the hardware controller was likely to be the issue, since
[memory cells](https://en.wikipedia.org/wiki/Flash_memory#Principles_of_operation)
may lose charge over time and can end up corrupting the content. We flashed
the latest firmware so the memory cells are charged again with the new bits and
that fixed the problem. Hopefully we will be able to use it for some more years.
The SLURM server has been moved to apex which allows users to also submit jobs
to fox.
### Migrated machines to BSC building
The server room had a temperature issue that had been affecting our machines
since the end of February of 2025. As the summer approached, the temperature
exceeded the safe limits for our hardware, so we had to shutdown the cluster.
![Room temperature](temp.png)
Since then, we have moved the cluster to BSC premises, where it now rests at a
stable temperature, so hopefully we won't have more unscheduled downtime.

Binary file not shown.

After