# Mark API
|
||||
|
||||
The mark API allows you to add arbitrary events in a trace to mark regions of
|
||||
interest while debugging or developing a new program or library. The events are
|
||||
processed by the emulator to generate a timeline.
|
||||
|
||||
## Usage in runtime
|
||||
|
||||
Follow these steps to correctly use the API. Most problems will be detected in
|
||||
emulation and cause a panic if you are not careful.
|
||||
|
||||
### Create a mark type
|
||||
|
||||
You can create up to 100 types of marks, each will be shown in its own Paraver
|
||||
timeline. To create a new type, use the following call:
|
||||
|
||||
```c
|
||||
void ovni_mark_type(int32_t type, long flags, const char *title);
|
||||
```
|
||||
|
||||
The numeric value `type` must be a number between 0 and 99 (both included). The
|
||||
`title` will be used to give a name to the Paraver timeline.
|
||||
|
||||
The default with flags set to zero, is to create a channel that can hold a
|
||||
single value only (see [channels](../../dev/channels.md)). To use a stack of
|
||||
values add the `OVNI_MARK_STACK` value to the flags.
|
||||
|
||||
### Define labels (optional)
|
||||
|
||||
The values that are written to the channel can have labels to display in the
|
||||
Paraver timeline. The labels are optional, if not given the numeric value will
|
||||
be shown in Paraver.
|
||||
|
||||
Use the following call to register a label for a value in a given type.
|
||||
|
||||
```c
|
||||
void ovni_mark_label(int32_t type, int64_t value, const char *label);
|
||||
```
|
||||
|
||||
### Emit events
|
||||
|
||||
All mark channels begin with the default value *null*, which is not shown in
|
||||
Paraver and will be displayed as the usual empty space.
|
||||
|
||||
If you have used a single channel (without `OVNI_MARK_STACK`), then you must use
|
||||
the following call to emit events at runtime:
|
||||
|
||||
```c
|
||||
void ovni_mark_set(int32_t type, int64_t value);
|
||||
```
|
||||
|
||||
It will update the value of the channel to the given `value`.
|
||||
|
||||
If you have used a stack channel (with `OVNI_MARK_STACK`), then you must use the
|
||||
push/pop set of calls:
|
||||
|
||||
```c
|
||||
void ovni_mark_push(int32_t type, int64_t value);
|
||||
void ovni_mark_pop(int32_t type, int64_t value);
|
||||
```
|
||||
|
||||
## Usage in Paraver
|
||||
|
||||
Each thread holds a channel for each mark type that you have defined. The
|
||||
information of the mark channels is propagated to the Paraver timeline in
|
||||
Thread and CPU views.
|
||||
|
||||
When a thread is not *running*, the value of the mark channels is not shown in
|
||||
Paraver. In the case of the CPU timeline, only the values of the running thread are
|
||||
shown. If there are no running threads, nothing is shown.
|
||||
|
||||
Follow the next steps to create a configuration to suit your needs. You only
|
||||
need to do it once, then you can save the configuration file and reuse it for
|
||||
future traces.
|
||||
|
||||
### Filtering the type
|
||||
|
||||
To see a mark type, you will have to create a Paraver configuration that matches
|
||||
the type that you have created. The mark `type` value gets converted into a PRV
|
||||
type by adding 100 (as values from 0 to 99 are reserved).
|
||||
|
||||
You can use the `cpu/ovni/mark.cfg` and `thread/ovni/mark.cfg` configurations as
|
||||
a starting point to create your own.
|
||||
|
||||
Go to "Window Properties" (the second button under "Files & Window Properties")
|
||||
and then go to Filter > Events > Event type. Set Function to `=` and click the
|
||||
Types value to display the `[...]` button, which will allow you to choose which
|
||||
type to display.
|
||||
|
||||
In the "Events Selection" window, ensure that only one type is selected, and the
|
||||
"Values" panel shows Function "All", to see all values for the selected type.
|
||||
|
||||
### Setting the title
|
||||
|
||||
In the "Window Properties" adjust the Name so it reflects what you are seeing.
|
||||
This will be shown in the saved images, so it is good to use a proper
|
||||
description.
|
||||
|
||||
### Configure the display method
|
||||
|
||||
By default, the timeline will display the values as "Code color". To switch to a
|
||||
gradient or other methods, left-click in the timeline and go to "Paint As" and
|
||||
select "Gradient" (or others).
|
||||
|
||||
You may also want to adjust the "Drawmode" which determines what happens when
|
||||
there are multiple values under a given pixel. This is specially important when
|
||||
you are viewing the trace with a large time range, before zooming into a given
|
||||
region.
|
||||
|
||||
By default, the "Random not zero" mode is selected, which will select a
|
||||
random value from the ones under each pixel, disregarding the occurrences of each
|
||||
value. This mode will give importance to rare values, so it is usually a safe
|
||||
starting point. The "Last" mode will show the last value in that pixel, which is
|
||||
more or less fair, but will often hide rare values.
|
||||
|
||||
To change in both horizontal (Time) and in vertical (Objects) directions, go to:
|
||||
left click on timeline > Drawmode > Both > Last.
|
||||
|
||||
### Ensure the range is good
|
||||
|
||||
Paraver will only display values in the timeline that are in the Semantic
|
||||
range. If you see a red triangle in the lower left corner then there are values
|
||||
outside the range that are not being displayed. You can click on this button to
|
||||
expand the range to cover all values in the current view.
|
||||
|
||||
The opposite may also happen, where the range is too big for the current values.
|
||||
You can also click on the same spot (even if the triangle is not shown) to
|
||||
shrink the range to cover the values in the view, or go to the Window Properties
|
||||
and modify the "Semantic Minimum" and "Semantic Maximum" values manually.
|
||||
|
||||
### Save the configuration
|
||||
|
||||
Once you finish configuring the timeline, save the configuration by
|
||||
left-clicking the view and then "Save > Configuration...". You can use this
|
||||
configuration in future traces to avoid doing these steps again.
|
@ -27,6 +27,7 @@ nav:
|
||||
- user/installation.md
|
||||
- 'Runtime':
|
||||
- user/runtime/tracing.md
|
||||
- user/runtime/mark.md
|
||||
- user/runtime/distributed.md
|
||||
- user/runtime/kernel.md
|
||||
- user/runtime/trace_spec.md
|
||||
|